OrcaDose
Sign in
Lung SABRadvancedtcia

4D-Lung · 102_HM10395

54 Gy in 3 fractions·contributed by 이강훈·2026-08-04

  1. 1

    Get the case

    A de-identified CT and structure set, as one archive. Plan it in your own system.

  2. 2

    Plan it

    The criteria are published before anyone plans and do not change mid-challenge. Below they are also written as entries for your own optimizer.

  3. 3

    Submit the dose

    Upload the RTDOSE. It is scored automatically against the criteria, and you are told when it lands.

Plan this case as

Cure is the goal — cover the target, then spare what you can.

Scoring criteria

80 points

How a number becomes points. A metric at or past Ideal earns its full points. At the Minimum it earns none, and between the two it is linear — halfway between minimum and ideal is half the points. Worse than the minimum is zero for that line, never negative, and the rest of the plan still scores. Breaching a hard constraint is different: the plan keeps its number and leaves the ranking. How scoring works in full →

Target

MetricMinimumIdealPoints
PTV V100%on Tumor_c80≥ 90≥ 9512
PTV D95on Tumor_c80≥ 95≥ 1008
PTV Dmaxon Tumor_c80≤ 140≤ 1255

Organs at risk

MetricMinimumIdealPoints
Lungs V20Gyon LLung_c80 + RLung_c80≤ 15≤ 812
Lungs meanon LLung_c80 + RLung_c80≤ 8≤ 48
SpinalCord D0.03ccon Cord_c80≤ 18≤ 1210
Esophagus D0.03ccon Esophagus_c80≤ 27≤ 206
Heart D0.03ccon Heart_c80≤ 30≤ 226

Plan quality

MetricMinimumIdealPoints
CIon Tumor_c80≤ 1.4≤ 1.055
GIon Tumor_c80≤ 6≤ 3.55
HIon Tumor_c80≤ 0.45≤ 0.23

Hard constraints

Breaching any of these removes the plan from the ranking, whatever it scored.

  • PTV V54Gy < 85%
  • SpinalCord D0.03cc > 20 Gy