OrcaDose
Sign in
Liver SBRTintermediateAI-generated CT

Synthetic liver SBRT · LIVER_50

50 Gy in 5 fractions·contributed by 이강훈·2026-08-05

This CT was generated by a model. No patient was scanned.

The anatomy is synthetic and the structures come from the generator rather than from a clinician. Treat the Hounsfield units as plausible rather than measured: there is no scanner behind them and so no CT-to-density calibration of yours applies, and because the image has no real counterpart the error in them cannot be quantified at all. It is a planning exercise, and every plan here is scored against the same geometry — but nothing learned from this case is a statement about a real patient.

  1. 1

    Get the case

    A de-identified CT and structure set, as one archive. Plan it in your own system.

  2. 2

    Plan it

    The criteria are published before anyone plans and do not change mid-challenge. Below they are also written as entries for your own optimizer.

  3. 3

    Submit the dose

    Upload the RTDOSE. It is scored automatically against the criteria, and you are told when it lands.

**This CT was generated by a model. No patient was scanned, and there is no real case behind it.** Produced with NVIDIA MAISI (3D latent diffusion) via MONAI, conditioned on a segmentation from the model's own candidate set, at 512×512×512 and 1 mm isotropic — the combination MAISI's own quality check passes. The Hounsfield units are the model's and have not been replaced; bone above 700 HU was stretched back into a cortical range to undo the training clip at 1000. Treat the HU as plausible rather than measured. There is no scanner behind this image, so no CT-to-density calibration of yours applies to it, and because the volume has no real counterpart the error in its densities cannot be quantified at all. Every plan submitted here is scored against the same geometry, so the ranking compares planners — but nothing learned from this case is a statement about a real patient. Target 6.6 cc in a 1438 cc liver. Liver_GTV is supplied rather than derived by the planner, so every plan is scored on the same denominator. Prescription is 50 Gy in 5 fractions per NRG/RTOG 1112; that trial lowered the dose when the liver mean could not be met, and this challenge does not. Target check: 6.6 cc, 1 piece(s) generated, +18.5 HU against the liver around it — below the platform's threshold of 20 HU contrast; the lesion is hard or impossible to see on the image.

Anatomy

scroll to move through the slices

Opening the CT series…